Thursday, January 8, 2015

Testing of push button switch using digital multi meter

testing of push button switch  using digital multi meter

components required for the testing of push button switch are 

1. push button switch  



2. digtal multi meter 



    procedure                                                                                                                                             

         step 1

                Connect the multi meter  with probes positive and negative  with signs given +, -.                                                    and keep the multi meter in buzzer mode
       
         Step 2
                  
                   connect the multi meter probes [ balck and red] to the push button  switch  terminals  as it has two terminals    

         step 3

                 push the buttton   of the switch  down wards to   make it ON  , and note the readings  of multi meter 


Note:

          check the reading of multi meter  should be 0.1 (or) 0.2 units
                                                                                                                                






Wednesday, January 7, 2015

Testing of diode BYQ 28 using digital multi meter

Testing of diode BYQ 28 using digital  multi meter

components required for the testing  of diode byq 28  are 

1. diode byq 28






2. digital multi meter 


The diode byq 28  has 
1. positive terminal 
2. ground  in middle 
3. negative terminal 



procedure :


step 1 

  connect the multi meter  with probes  positive  and negative  with signs given + , - 

step 2 
  
Make middle pin 2 as ground  and with  - probe[ black probe] and test both sides of the diode that is   pin  1 and pin 3 and note the readings 

 step 3

make mibble pin 2 as ground with + probe  [ red probe ] and test  both sides  of  pin 1 and pin 3  and note the  readings 

note:

check that the multi meter reading should be  above . 400 units 


Tuesday, January 6, 2015

Testing of variable resistor of 504w using digital multi meter

Testing of  variable resistor of 504 w

components required for testing of variable resistor or potentio meter  are 

1. variable resistor







2. digital multi meter with probes


3. bread board 


4. connecting wires                                                                                                                              
  5. screw driver                                                                                                                                                            




        procedure :                                                                                                                                                                                                                                                                                                                                                     

                step 1                                                                                                                                                          
 connect the multimeter  with probes  positive  and negative  with signs given + , -      



           step 2                                                                                                                                  

connect  the  multi meter probes and connecting wires                                              

                          

               step 3                                                                                                                                            
 place these connnecting wires  in the bread board                                                  


                                                                                                                                                                                      step 4                                                                                                                                                              Then place the variable  resistor  in series of the  connecting wires   and see the  reading of themulti meter   it will be .300  then place the  tester or screw driver on the   variable resistor  screw and rotate anti clock wise  until 000 units and then  rotate clock  wise  until .500  units or it should be plus + or minus- 10 that of .500                                                                                                                                                                    

  note :                                                                                                                         

                       check the multi meter readings correctly it should be + or - 10 percent that of .500  units                                                                                                                                                                 

                                                                                                                                                                                 














Sunday, January 4, 2015

Testing of bridge rectifier Using Digital Multi Meter

Hello  guys I will make you easy to understand  that how to test a  bridge rectifier using a digital Multi meter  today in a very simple and easy steps.                                                                            

Components required :

Bridge rectifier

Multi meter with probes

Procedure :

Step 1 

Connect the multi meter  with probes positive and negative  with signs given +, -.

Step 2

Connect the positive terminal of bridge rectifier which is shown in the figure  to the negative terminal,that is black wire of multi meter and check  the both sides of positive terminal of bridge rectifier with the red wire of multi meter

step 3

Now, note the readings.

step 4

Then connect the red wire of multi meter to the pin of  bridge rectifier which is diagonal to the positive terminal of rectifier and then check both sides of this pin with  black wire that is negative wire and note the readings.


Note

  The readings of the multi meter should be more than  . 400 units